{"id":3685,"date":"2019-07-22T14:18:57","date_gmt":"2019-07-22T14:18:57","guid":{"rendered":"http:\/\/eng.beia-telemetrie.ro\/?page_id=3685"},"modified":"2019-07-22T14:18:57","modified_gmt":"2019-07-22T14:18:57","slug":"wind-energy","status":"publish","type":"page","link":"http:\/\/eng.beia-telemetrie.ro\/?page_id=3685","title":{"rendered":"Wind energy"},"content":{"rendered":"<ol>\n<li><strong>Contract object:<\/strong><\/li>\n<\/ol>\n<p>Outdoor wind potential measurement system<\/p>\n<p><strong>\u00a0<\/strong><\/p>\n<ol start=\"2\">\n<li><strong>Beneficiary:<\/strong><\/li>\n<\/ol>\n<p>University Transilvania from Brasov \/ ProDD Institute Brasov<\/p>\n<p>&nbsp;<\/p>\n<ol start=\"3\">\n<li><strong>System delivery date<\/strong>:<\/li>\n<\/ol>\n<p>Q4 \/ 2012<\/p>\n<p>&nbsp;<\/p>\n<ol start=\"4\">\n<li><strong>Minimum technical requirements requested by the beneficiary:<\/strong><\/li>\n<\/ol>\n<ul>\n<li>The test stand must be portable, the materials used to be resistant and light;<\/li>\n<li>Data acquisition system;<\/li>\n<li>Software for data processing;<\/li>\n<li>Independent energy system.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<ol start=\"5\">\n<li><strong>Structure of the delivered system:<\/strong><\/li>\n<\/ol>\n<p>3 x Measuring stations located individuallyin areas with coverage with GSM-GPRS;<\/p>\n<p>&nbsp;<\/p>\n<p>Component one (1) measuring station:<\/p>\n<ul>\n<li>1 x RTU tip ADCON A753 (Remote Terminal Unit = RTU);<\/li>\n<li>1 x set Anemometru-Girueta de tipul Adcon Pro 10;<\/li>\n<li>1 x propeller anemometer(propeller) Gill type (this product was installed on just 2 of the 3 measuring stations);<\/li>\n<li>1 x An anemometer of the Adcon Win 10 type (without girueta; only 1 station has been installed);<\/li>\n<li>1 x Combined temperature and humidity sensor type Adcon TR1;<\/li>\n<li>1 x solar panel;<\/li>\n<li>1 x mast \/ pole on which the measuring station was installed<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p>1 x Data Center located at the ProDD Brasov Institute<\/p>\n<p>&nbsp;<\/p>\n<p>Component:<\/p>\n<ul>\n<li>1 x Concentrator of data (gateway) of type Adcon A850;<\/li>\n<li>1 x Statie grafica pentru prelucrarea si afisarea datelor culese de concentratorul de date;<\/li>\n<li>1 x software license type Adcon addVANTAGE Pro 6.1 server for 1 User\/5 RTU.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n<p><strong>6.The way data is measured, transmitted and presented<\/strong><\/p>\n<p>The output of each of the sensors mentioned in the measuring station component is read by the RTU once every 3 minutes. Every 15 minutes, RTU calculates an average of the 5 measurements made in that range. Every hour, RTU transmits to the center the 4 average values \u200b\u200bcalculated for each parameterRTU p\u0103streaza parametrii prelua\u0163i de la senzori pe perioade de indisponibilitate a comunica\u0163iei cu centrul de date care vor putea ajunge p\u00e2n\u0103 la 15 zile.<\/p>\n<p>&nbsp;<\/p>\n<p>Adcon addVantage Pro 6.1 provides the presentation of measured data in the form of \u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0\u00a0tables and in the form of time slots. There are multiple possibilities of viewing data for different past periods (from the order of the hours to the order of the years), displaying the values \u200b\u200bat the desired date, time, minute, and second. Two examples of the presentation format of the processed data are given in Figures 1 and 2 on page 3.<\/p>\n<p>The Data Center kept primary data and data processed for at least 2 years prior to the current date.The Data Center allows the processed data to be made available via the Internet to any user who can login by user name and password. There are extensive possibilities for configuring user rights.<\/p>\n<p><a href=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1.png\"><img loading=\"lazy\" decoding=\"async\" class=\"wp-image-3681 aligncenter\" src=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1.png\" alt=\"\" width=\"511\" height=\"346\" srcset=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1.png 954w, http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1-300x203.png 300w, http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1-768x519.png 768w\" sizes=\"auto, (max-width: 511px) 100vw, 511px\" \/><\/a><\/p>\n<p><a href=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture2.png\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-3682 aligncenter\" src=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture2.png\" alt=\"\" width=\"532\" height=\"372\" srcset=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture2.png 944w, http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture2-300x210.png 300w, http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture2-768x537.png 768w\" sizes=\"auto, (max-width: 532px) 100vw, 532px\" \/><\/a><\/p>\n<p><strong>7.Photos from the installation and commissioning of the measuring stations<\/strong><\/p>\n<p><a href=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Capture.png\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-3683 aligncenter\" src=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Capture.png\" alt=\"\" width=\"554\" height=\"630\" srcset=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Capture.png 554w, http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Capture-264x300.png 264w\" sizes=\"auto, (max-width: 554px) 100vw, 554px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Contract object: Outdoor wind potential measurement system \u00a0 Beneficiary: University Transilvania from Brasov \/ ProDD Institute Brasov &nbsp; System delivery date: Q4 \/ 2012 &nbsp; Minimum technical requirements requested by the beneficiary: The test stand must be portable, the materials used to be resistant and light; Data acquisition system; Software\u2026 <a href=\"http:\/\/eng.beia-telemetrie.ro\/?page_id=3685\" class=\"read-more-link\">read more &rarr;<\/a><\/p>\n","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-3685","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Wind energy - BEIA Telemetry, Telemonitoring - Adcon, OTT<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Wind energy - BEIA Telemetry, Telemonitoring - Adcon, OTT\" \/>\n<meta property=\"og:description\" content=\"Contract object: Outdoor wind potential measurement system \u00a0 Beneficiary: University Transilvania from Brasov \/ ProDD Institute Brasov &nbsp; System delivery date: Q4 \/ 2012 &nbsp; Minimum technical requirements requested by the beneficiary: The test stand must be portable, the materials used to be resistant and light; Data acquisition system; Software\u2026 read more &rarr;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685\" \/>\n<meta property=\"og:site_name\" content=\"BEIA Telemetry, Telemonitoring - Adcon, OTT\" \/>\n<meta property=\"og:image\" content=\"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1.png\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/eng.beia-telemetrie.ro\\\/?page_id=3685\",\"url\":\"https:\\\/\\\/eng.beia-telemetrie.ro\\\/?page_id=3685\",\"name\":\"Wind energy - BEIA Telemetry, Telemonitoring - Adcon, OTT\",\"isPartOf\":{\"@id\":\"http:\\\/\\\/eng.beia-telemetrie.ro\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/eng.beia-telemetrie.ro\\\/?page_id=3685#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/eng.beia-telemetrie.ro\\\/?page_id=3685#primaryimage\"},\"thumbnailUrl\":\"http:\\\/\\\/eng.beia-telemetrie.ro\\\/wp-content\\\/uploads\\\/sites\\\/8\\\/2019\\\/07\\\/Picture1.png\",\"datePublished\":\"2019-07-22T14:18:57+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/eng.beia-telemetrie.ro\\\/?page_id=3685#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/eng.beia-telemetrie.ro\\\/?page_id=3685\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/eng.beia-telemetrie.ro\\\/?page_id=3685#primaryimage\",\"url\":\"http:\\\/\\\/eng.beia-telemetrie.ro\\\/wp-content\\\/uploads\\\/sites\\\/8\\\/2019\\\/07\\\/Picture1.png\",\"contentUrl\":\"http:\\\/\\\/eng.beia-telemetrie.ro\\\/wp-content\\\/uploads\\\/sites\\\/8\\\/2019\\\/07\\\/Picture1.png\",\"width\":954,\"height\":645},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/eng.beia-telemetrie.ro\\\/?page_id=3685#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Acas\u0103\",\"item\":\"http:\\\/\\\/eng.beia-telemetrie.ro\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Wind energy\"}]},{\"@type\":\"WebSite\",\"@id\":\"http:\\\/\\\/eng.beia-telemetrie.ro\\\/#website\",\"url\":\"http:\\\/\\\/eng.beia-telemetrie.ro\\\/\",\"name\":\"BEIA Telemetry, Telemonitoring - Adcon, OTT\",\"description\":\"BEIA Telemetry, Telemonitoring - Adcon, OTT\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"http:\\\/\\\/eng.beia-telemetrie.ro\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Wind energy - BEIA Telemetry, Telemonitoring - Adcon, OTT","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685","og_locale":"en_US","og_type":"article","og_title":"Wind energy - BEIA Telemetry, Telemonitoring - Adcon, OTT","og_description":"Contract object: Outdoor wind potential measurement system \u00a0 Beneficiary: University Transilvania from Brasov \/ ProDD Institute Brasov &nbsp; System delivery date: Q4 \/ 2012 &nbsp; Minimum technical requirements requested by the beneficiary: The test stand must be portable, the materials used to be resistant and light; Data acquisition system; Software\u2026 read more &rarr;","og_url":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685","og_site_name":"BEIA Telemetry, Telemonitoring - Adcon, OTT","og_image":[{"url":"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1.png","type":"","width":"","height":""}],"twitter_misc":{"Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685","url":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685","name":"Wind energy - BEIA Telemetry, Telemonitoring - Adcon, OTT","isPartOf":{"@id":"http:\/\/eng.beia-telemetrie.ro\/#website"},"primaryImageOfPage":{"@id":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685#primaryimage"},"image":{"@id":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685#primaryimage"},"thumbnailUrl":"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1.png","datePublished":"2019-07-22T14:18:57+00:00","breadcrumb":{"@id":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/eng.beia-telemetrie.ro\/?page_id=3685"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685#primaryimage","url":"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1.png","contentUrl":"http:\/\/eng.beia-telemetrie.ro\/wp-content\/uploads\/sites\/8\/2019\/07\/Picture1.png","width":954,"height":645},{"@type":"BreadcrumbList","@id":"https:\/\/eng.beia-telemetrie.ro\/?page_id=3685#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Acas\u0103","item":"http:\/\/eng.beia-telemetrie.ro\/"},{"@type":"ListItem","position":2,"name":"Wind energy"}]},{"@type":"WebSite","@id":"http:\/\/eng.beia-telemetrie.ro\/#website","url":"http:\/\/eng.beia-telemetrie.ro\/","name":"BEIA Telemetry, Telemonitoring - Adcon, OTT","description":"BEIA Telemetry, Telemonitoring - Adcon, OTT","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"http:\/\/eng.beia-telemetrie.ro\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"http:\/\/eng.beia-telemetrie.ro\/index.php?rest_route=\/wp\/v2\/pages\/3685","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/eng.beia-telemetrie.ro\/index.php?rest_route=\/wp\/v2\/pages"}],"about":[{"href":"http:\/\/eng.beia-telemetrie.ro\/index.php?rest_route=\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"http:\/\/eng.beia-telemetrie.ro\/index.php?rest_route=\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"http:\/\/eng.beia-telemetrie.ro\/index.php?rest_route=%2Fwp%2Fv2%2Fcomments&post=3685"}],"version-history":[{"count":1,"href":"http:\/\/eng.beia-telemetrie.ro\/index.php?rest_route=\/wp\/v2\/pages\/3685\/revisions"}],"predecessor-version":[{"id":3686,"href":"http:\/\/eng.beia-telemetrie.ro\/index.php?rest_route=\/wp\/v2\/pages\/3685\/revisions\/3686"}],"wp:attachment":[{"href":"http:\/\/eng.beia-telemetrie.ro\/index.php?rest_route=%2Fwp%2Fv2%2Fmedia&parent=3685"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}